To help agencies specifically keep track of the Air Leakage/Sealing Compliance Method on dwelling construction- a new inspection type called 1465 Blower Door has been added to the Model.
When agencies begin their residential plan review, it is recommended that they PEND this inspection to the record when the plans indicate that the dwelling should be tested to demonstrate the blower door result (rather than a declaration that they are meeting the requirements of Table N1104.8). Please note the related citation for your information: N1104.8.2 Sealing required. Exterior joints around window and door frames, between wall cavities and window or door frames, between walls and foundation, between walls and roof, between wall panels, at penetrations or utility services through walls, floors and roofs and all other openings in the exterior envelope shall be sealed in a manner approved by the building official. Sealing for the purpose of creating a continuous air barrier shall be in accordance with the applicable requirements of Table N1104.8 or the dwelling shall be tested to demonstrate a blower door result not greater than 4.0 ACH50.
0 Comments